Flagged cases and users are reviewed withing 24 - 48 hours upon submission of a report. The report will be reviewed to determine whether the case and it's author (user) has violated Medzcool's Terms of Use and/or Community Guidelines. Accounts are penalized for violations to either the Terms of Use and/or Community Guidlines. Repeated violations can lead to account termination.

Thank you for your report, it will be reviewed within the next 24-48 hrs.
Chief Complaint:

Ventricular Assist Devices

Published: July 7, 2017
Case No. 57
Author: Jason2475
CASE SCENARIO

A patient presents to the cardiologist office for routine follow-up. He has a left ventricular assist device (LVAD) for severe heart failure. The patient states he was reading online about blood clots and LVADs. He is on warfarin and is compliant with his medications. He has no complaints at this time.

QUESTION

A thrombus located in the rotor of an LVAD will likely present with which of the following

Increased flow state
Increased revolutions per minute (RPM)
Increased pulsatility index (PI)
Increased power